2.0 Installation
WARNING
Insufficient ventilation may result in fire, explosion, health problems, carbon monoxide
poisoning, serious injury or death. Vent enclosed spaces and buildings according to national,
state, provincial and local codes.
Overfilled LP gas cylinders may cause explosion, fire, property damage, serious injury or
death. Indications of an overfilled LP gas cylinder include failure to light and/or pressure
buildup on the regulator. Return overfilled tank to the supplier and inspect the hose and
regulator for damage.
Using any heater component (e.g., manifold, gas valve, gas line connector) for support may
result in the heater tipping over and causing injury, fire or explosion. Always locate the
heater on a stable, secure and level surface.
Installation
Prior to installation, verify the heater’s gas type as listed on the rating plate. Installation of this heater must
conform with local codes or, in the absence of local codes, with the Standard for the Storage and
Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and the Natural Gas and Propane Installation
Code, CSA B149.1.
LP gas models are approved for use with a DOT 20 lb. LP gas cylinder with a 10 inch diameter base
(NOTE: only use a vapor withdraw type cylinder. Do not use a forklift truck or liquid dispensing cylinder).
See Chart 2.2 Operating Values for pressure specifications.
Along with maintaining the clearance to combustibles, the heater must be used in a well ventilated area.
When the heater is temporarily used in an enclosed area, a positive air displacement of at least 4.0 CFM
per 1,000 BTU/h of the heater’s rated input must be provided.
Locate the heater on a stable, level surface and at least 10 feet away from canvas, tarpaulins or similar
coverings and secure such coverings to prevent ignition and interference with the heater. The heater must
be at least 6 ft. from other LP gas containers and have at least 20 ft. between containers in the direction of
the projected heat.
The use of the heater in drafty conditions may result in the loss of heater efficiency. In drafty conditions
turn the heater so it faces away from the direction of the draft/wind. The heater must be placed or installed
such that it is not directly exposed to water spray, rain and/or dripping water.
2.0 Installation Assembly
Read and understand, the installation, operating and maintenance instructions thoroughly
before assembling or operating this equipment.